感染诱发的老年多器官功能障碍综合征(infection induced multiple organ dysfunction syndrome in the elderly,i MODSE)是指老年人(≥65岁)在器官老化和患有多种慢性疾病的基础上,由感染激发、短时间内序贯或同时发生2个或2个以上器...感染诱发的老年多器官功能障碍综合征(infection induced multiple organ dysfunction syndrome in the elderly,i MODSE)是指老年人(≥65岁)在器官老化和患有多种慢性疾病的基础上,由感染激发、短时间内序贯或同时发生2个或2个以上器官功能障碍或衰竭的综合征[1, 2]。王士雯院士于20世纪80年代末在国际上首先提出了老年多器官功能衰竭(multiple organ failure in the elderly,MOFE)的概念[3]。1991年,美国胸科医师协会/危重病医学会(ACCP/SCCM)将多器官功能衰竭(multiple organ failure,MOF)更名为多器官功能障碍综合征(multiple organ dysfunction syndrome,MODS)[4]。展开更多
Based on the inhibition by hydroquinone, catechol and resorcinol of chemiluminescence from luminol potassium hexacyanoferrate(Ⅲ) system, a high performance liquid chromatographic procedure with chemiluminescent detec...Based on the inhibition by hydroquinone, catechol and resorcinol of chemiluminescence from luminol potassium hexacyanoferrate(Ⅲ) system, a high performance liquid chromatographic procedure with chemiluminescent detection was developed for simultaneous determination of hydroquinone, catechol and resorcinol. The separation was carried out on RP C 18 column at 37 ℃ by using a step gradient elution made by the mobile phases of methanol(A) and 0 05% H 3PO 4(B). The gradient elution condition was 95% B, 5 min; 95%B 50%B, 1 min; 50% B, 6 min. This method has the merits of high senstivity and good selectivity. The detection limits for hydroquinone, catechol and resorcinol are 2 0×10 -9 , 3 2×10 -9 and 6 8×10 -7 g/mL, respectively. The relative standard deviation( n =5) is 1 9% for 2 5×10 -7 g/mL hydroquinone, 1 0% for 7 5×10 -7 g/mL catechol, 4 0% for 5 0×10 -5 g/mL resorcinol, respectively. The recovery is in the range of 94%—104%. [WT5HZ]展开更多
文摘感染诱发的老年多器官功能障碍综合征(infection induced multiple organ dysfunction syndrome in the elderly,i MODSE)是指老年人(≥65岁)在器官老化和患有多种慢性疾病的基础上,由感染激发、短时间内序贯或同时发生2个或2个以上器官功能障碍或衰竭的综合征[1, 2]。王士雯院士于20世纪80年代末在国际上首先提出了老年多器官功能衰竭(multiple organ failure in the elderly,MOFE)的概念[3]。1991年,美国胸科医师协会/危重病医学会(ACCP/SCCM)将多器官功能衰竭(multiple organ failure,MOF)更名为多器官功能障碍综合征(multiple organ dysfunction syndrome,MODS)[4]。
文摘Based on the inhibition by hydroquinone, catechol and resorcinol of chemiluminescence from luminol potassium hexacyanoferrate(Ⅲ) system, a high performance liquid chromatographic procedure with chemiluminescent detection was developed for simultaneous determination of hydroquinone, catechol and resorcinol. The separation was carried out on RP C 18 column at 37 ℃ by using a step gradient elution made by the mobile phases of methanol(A) and 0 05% H 3PO 4(B). The gradient elution condition was 95% B, 5 min; 95%B 50%B, 1 min; 50% B, 6 min. This method has the merits of high senstivity and good selectivity. The detection limits for hydroquinone, catechol and resorcinol are 2 0×10 -9 , 3 2×10 -9 and 6 8×10 -7 g/mL, respectively. The relative standard deviation( n =5) is 1 9% for 2 5×10 -7 g/mL hydroquinone, 1 0% for 7 5×10 -7 g/mL catechol, 4 0% for 5 0×10 -5 g/mL resorcinol, respectively. The recovery is in the range of 94%—104%. [WT5HZ]