As a non-destructive testing technology,neutron imaging plays an important role in various fields,including material science,nuclear engineering,and fundamental science.An imaging detector with a neutron-sensitive ima...As a non-destructive testing technology,neutron imaging plays an important role in various fields,including material science,nuclear engineering,and fundamental science.An imaging detector with a neutron-sensitive image intensifier has been developed and demonstrated to achieve good spatial resolution and timing resolution.However,the influence of the working voltage on the performance of the neutron-sensitive imaging intensifier has not been studied.To optimize the performance of the neutron-sensitive image intensifier at different voltages,experiments have been performed at the China Spallation Neutron Source(CSNS)neutron beamline.The change in the light yield and imaging quality with different voltages has been acquired.It is shown that the image quality benefits from the high gain of the microchannel plate(MCP)and the high accelerating electric field between the MCP and the screen.Increasing the accelerating electric field is more effective than increasing the gain of MCPs for the improvement of the imaging quality.Increasing the total gain of the MCP stack can be realized more effectively by improving the gain of the standard MCP than that of the n MCP.These results offer a development direction for image intensifiers in the future.展开更多
To perform a kinematically complete measurement of the dissociation reaction for neutron-rich nuclei, a multi-neutron correlation spectrometer is proposed at Peking University. A Monte Carlo simulation code based on G...To perform a kinematically complete measurement of the dissociation reaction for neutron-rich nuclei, a multi-neutron correlation spectrometer is proposed at Peking University. A Monte Carlo simulation code based on GEANT4 is developed for a single scintillation bar which processes not only the energy deposition but also the light propagation in the scintillator and the light collection and conversion to signal at the end of the bar in a realistic way. The simulating method is described in detail in this paper, and the timing and position resolutions and detector efficiency are studied based on the simulation and compared with the experimental results. A new method of crosstalk rejection has been demonstrated to be important for the design of the whole spectrometer.展开更多
基金Project supported by the National Key R&D Program of China (Grant Nos.2023YFC2206502 and 2021YFA1600703)the National Natural Science Foundation of China (Grant Nos.12175254 and 12227810)the Guangdong–Hong Kong–Macao Joint Laboratory for Neutron Scattering Science and Technology。
文摘As a non-destructive testing technology,neutron imaging plays an important role in various fields,including material science,nuclear engineering,and fundamental science.An imaging detector with a neutron-sensitive image intensifier has been developed and demonstrated to achieve good spatial resolution and timing resolution.However,the influence of the working voltage on the performance of the neutron-sensitive imaging intensifier has not been studied.To optimize the performance of the neutron-sensitive image intensifier at different voltages,experiments have been performed at the China Spallation Neutron Source(CSNS)neutron beamline.The change in the light yield and imaging quality with different voltages has been acquired.It is shown that the image quality benefits from the high gain of the microchannel plate(MCP)and the high accelerating electric field between the MCP and the screen.Increasing the accelerating electric field is more effective than increasing the gain of MCPs for the improvement of the imaging quality.Increasing the total gain of the MCP stack can be realized more effectively by improving the gain of the standard MCP than that of the n MCP.These results offer a development direction for image intensifiers in the future.
基金Supported by National Basic Research Program (973 Program) of China (2007CB815002)National Natural Science Founda-tion of China (10827505, 10775003, 10475004, 10405001, J0730316)
文摘To perform a kinematically complete measurement of the dissociation reaction for neutron-rich nuclei, a multi-neutron correlation spectrometer is proposed at Peking University. A Monte Carlo simulation code based on GEANT4 is developed for a single scintillation bar which processes not only the energy deposition but also the light propagation in the scintillator and the light collection and conversion to signal at the end of the bar in a realistic way. The simulating method is described in detail in this paper, and the timing and position resolutions and detector efficiency are studied based on the simulation and compared with the experimental results. A new method of crosstalk rejection has been demonstrated to be important for the design of the whole spectrometer.