The Neighbor Cell Deposited Energy Ratio (NCDER) is a new method that is proposed to reconstruct incidence position in a single layer for a 3-dimensional imaging electromagnetic calorimeter (ECAL). This method was...The Neighbor Cell Deposited Energy Ratio (NCDER) is a new method that is proposed to reconstruct incidence position in a single layer for a 3-dimensional imaging electromagnetic calorimeter (ECAL). This method was applied to reconstruct the ECAL test beam data for the Alpha Magnetic Spectrometer-02 (AMS-02). The results show that this method can achieve an angular resolution of 7.36±0.08°/√E+0.28±0.02° in the determination of the photon's direction, which is much more precise than that obtained with the commonly-adopted Center of Gravity (COG) method (8.4±0.1°/E+0.8±0.3°). Furthermore, since it uses only the properties of electromagnetic showers, this new method could also be used for other type of fine grain sampling calorimeters.展开更多
The position effect of the photoelectron multiplier tube (PMT) of the electromagnetic calorimeter (ECAL) of Alpha Magnetic Spectrometer-02 (AMS-02) has been studied with beam-test data. The reconstructed deposit...The position effect of the photoelectron multiplier tube (PMT) of the electromagnetic calorimeter (ECAL) of Alpha Magnetic Spectrometer-02 (AMS-02) has been studied with beam-test data. The reconstructed deposited energy in a layer versus incidence position in the cell can be described by Gaussian distribution, maximum and minimum value can be obtained when the particle passes across the center and the edge of a cell respectively. The distribution can be used to correct the effect of incidence position on energy reconstruction. Much better energy resolution was acquired be got with the correction, for 100 GeV electrons, energy resolution improved from 3% to 2%.展开更多
基金Supported by China National Science Foundation(10805050)
文摘The Neighbor Cell Deposited Energy Ratio (NCDER) is a new method that is proposed to reconstruct incidence position in a single layer for a 3-dimensional imaging electromagnetic calorimeter (ECAL). This method was applied to reconstruct the ECAL test beam data for the Alpha Magnetic Spectrometer-02 (AMS-02). The results show that this method can achieve an angular resolution of 7.36±0.08°/√E+0.28±0.02° in the determination of the photon's direction, which is much more precise than that obtained with the commonly-adopted Center of Gravity (COG) method (8.4±0.1°/E+0.8±0.3°). Furthermore, since it uses only the properties of electromagnetic showers, this new method could also be used for other type of fine grain sampling calorimeters.
基金Supported by National Natural Science Foundation of China (10805050)
文摘The position effect of the photoelectron multiplier tube (PMT) of the electromagnetic calorimeter (ECAL) of Alpha Magnetic Spectrometer-02 (AMS-02) has been studied with beam-test data. The reconstructed deposited energy in a layer versus incidence position in the cell can be described by Gaussian distribution, maximum and minimum value can be obtained when the particle passes across the center and the edge of a cell respectively. The distribution can be used to correct the effect of incidence position on energy reconstruction. Much better energy resolution was acquired be got with the correction, for 100 GeV electrons, energy resolution improved from 3% to 2%.