Interaction between rare earth ion praseodymium (Pr(Ⅲ)) and MP11 with/without hydrogen ion (H +) in different media( aqueous, phosphate buffer, physiological condition) were studied by UV Vis spectroscopy. All the ...Interaction between rare earth ion praseodymium (Pr(Ⅲ)) and MP11 with/without hydrogen ion (H +) in different media( aqueous, phosphate buffer, physiological condition) were studied by UV Vis spectroscopy. All the results indicate that Pr(Ⅲ) interacts with MP11, increasing the non planarity of porphyrin periphery, leading MP11 to form two conformations when titrated by Pr(Ⅲ). Excessive Pr(Ⅲ) acts as a contaminant in living organism. H + and Pr(Ⅲ) have antagonistic effect on MP11, suggesting that at suitable concentration under physiological conditions, Pr(Ⅲ) can be used as biomodulator in protecting plants from acid rain stress or in rehabilitating the harm.展开更多
A new method for the determination of trace non-rare earth elements in high purity rare earth oxides by ICP-AES with preconcentration on an active carbon-silica gel microcolumn in a flow injection system is described ...A new method for the determination of trace non-rare earth elements in high purity rare earth oxides by ICP-AES with preconcentration on an active carbon-silica gel microcolumn in a flow injection system is described in this paper. Experimental parameters such as pH, flow rate,reagent concentration,length of reaction coil,eluent acidity,etc. were optimized. In the buffer solution of NH3. H2O/NH4Cl at pH 4. 6,Al,Cr,Cu,Fe, Pb, V and Zn can be preconcentrated and then eluted with 4. 5 mol/L nitric acid utilizing stop-flow technique. The enrichment factors were in range of 8. 1 ̄12. 6 with detection limits of μg/m level ,and the RSD with metals at μg/g level were 2. 3 ̄5. 0% (n= 7). The method proposed can reduce the matrix interference effectively , and has been applied to the determination of non-rare earth metals atμg/g level in high purity Eu2O3 with satisfactory results.展开更多
文摘Interaction between rare earth ion praseodymium (Pr(Ⅲ)) and MP11 with/without hydrogen ion (H +) in different media( aqueous, phosphate buffer, physiological condition) were studied by UV Vis spectroscopy. All the results indicate that Pr(Ⅲ) interacts with MP11, increasing the non planarity of porphyrin periphery, leading MP11 to form two conformations when titrated by Pr(Ⅲ). Excessive Pr(Ⅲ) acts as a contaminant in living organism. H + and Pr(Ⅲ) have antagonistic effect on MP11, suggesting that at suitable concentration under physiological conditions, Pr(Ⅲ) can be used as biomodulator in protecting plants from acid rain stress or in rehabilitating the harm.
文摘A new method for the determination of trace non-rare earth elements in high purity rare earth oxides by ICP-AES with preconcentration on an active carbon-silica gel microcolumn in a flow injection system is described in this paper. Experimental parameters such as pH, flow rate,reagent concentration,length of reaction coil,eluent acidity,etc. were optimized. In the buffer solution of NH3. H2O/NH4Cl at pH 4. 6,Al,Cr,Cu,Fe, Pb, V and Zn can be preconcentrated and then eluted with 4. 5 mol/L nitric acid utilizing stop-flow technique. The enrichment factors were in range of 8. 1 ̄12. 6 with detection limits of μg/m level ,and the RSD with metals at μg/g level were 2. 3 ̄5. 0% (n= 7). The method proposed can reduce the matrix interference effectively , and has been applied to the determination of non-rare earth metals atμg/g level in high purity Eu2O3 with satisfactory results.