Assessment of Control Configurations for a General Heat Integrated Distillation Column 被引量:2
1
作者 黄克谨 钱积新 +2 位作者 中岩勝 中根 高松武一郎 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2000年第4期339-346,共8页
The assessment of control configurations for an ideal heat integrated distillation column incorporated with an overhead condenser and a bottom reboiler (general HIDiC) is addressed in this work. It is found that doubl... The assessment of control configurations for an ideal heat integrated distillation column incorporated with an overhead condenser and a bottom reboiler (general HIDiC) is addressed in this work. It is found that double ratio control configuration, (L/D, V/B), is still the best one among all the possibilities. The control configuration,(Pr - Ps, q), appears to be a feasible one for the general HIDiC and the pressure difference between the rectifying and the stripping sections and feed thermal condition are expected to be consistent manipulative variables for the process. The performance of the general HIDiC can be substantially improved by employing effective multivariable control algorithms. 展开更多
关键词 DISTILLATION control configuration INTERACTION disturbance rejection closed-loop simulation