From 2011 to 2014, the BESIII experiment collected about 5 fb^-1 data at center-of-mass energies around 4 GeV for the studies of the charmonium-like and higher excited charmonium states. By analyzing the di-muon proce...From 2011 to 2014, the BESIII experiment collected about 5 fb^-1 data at center-of-mass energies around 4 GeV for the studies of the charmonium-like and higher excited charmonium states. By analyzing the di-muon process e+e- →yma/Fsμ^+μ^-, the center-of-mass energies of the data samples are measured with a precision of 0.8 MeV. The center-of-mass energy is found to be stable for most of the time during data taking.展开更多
基金Supported by National Key Basic Research Program of China(2015CB856700)National Natural Science Foundation of China(11125525,11235011.11322544,11335008,11425524,Y61137005C)+7 种基金Chinese Academy of Sciences(CAS)Large-Scale Scientific Facility Program,CAS Center for Excellence in Particle Physics(CCEPP),Collaborative Innovation Center for Particles and Interactions(CICPI),Joint Large-Scale Scientific Facility Funds of NSFC and CAS(11179007,U1232201,U1332201),CAS(KJCX2-YW-N29,KJCX2-YWN45),100 Talents Program of CASNational 1000 Talents Program of China,INPACShanghai Key Laboratory for Particle Physics and Cosmology,German Research Foundation DFG(Collaborative Research Center CRC-1044)Istituto Nazionale di Fisica Nucleare,Italy,Ministry of Development of Turkey(DPT2006K-120470)Russian Foundation for Basic Research(14-07-91152)Swedish Research Council,U.S.Department of Energy(DE-FG02-04ER41291,DE-FG02-05ER41374,DE-FG02-94ER40823,DESC0010118)U.S.National Science Foundation,University of Groningen(RuG)and Helniholtzzentrum fuer Schwerionenforschung GmbH(GSI),DarmstadtWCU Program of National Research Foundation of Korea(R32-2008-000-10155-0)
文摘From 2011 to 2014, the BESIII experiment collected about 5 fb^-1 data at center-of-mass energies around 4 GeV for the studies of the charmonium-like and higher excited charmonium states. By analyzing the di-muon process e+e- →yma/Fsμ^+μ^-, the center-of-mass energies of the data samples are measured with a precision of 0.8 MeV. The center-of-mass energy is found to be stable for most of the time during data taking.
基金supported by Beijing Municipal Administration of Hospitals Clinical Medicine Development of Special Funding Support(ZYLX201411)Project of Health Technical Personnel of Beijing Health System(2011-2-13)Beijing Ten Disease of Ten Drugs-Renzhu Jianpi Liqi Granules Pre Clinical Study(Z131100002513012)~~