摘要 图像引导是精准放射治疗用以定位肿瘤靶区以及周围危及器官的基本手段。与MR扫描仪相比,基于X射线成像的影像设备具有软组织对比度差和辐射性等缺点。因此将MR扫描仪与放射治疗机相结合的一体化、实时MRI引导的放射治疗(MRIgRT)技术成为放射治疗的一个新方向。本文就MRIgRT的技术优势,国内外相关MRIgRT设备的研发动态,以及MRI引导放射治疗的技术难点进行综述。 Being the basic means in accurate and precise radiotherapy, image-guided radiotherapy can target the tumor and visualize the adjacent organs at risk.Compared with MR scanners,imaging devices based on X-ray imaging have disadvantages such as poor soft tissue contrast and radiation.In recent years,the integrated and real-time MR imaging-guided radiotherapy (MRIgRT) technology,which combines MR scanner and the radiotherapy machine,open a new horizon in radiation therapy.The technical advantages of MRIgRT,the research status of MRIgRT equipment at home and abroad,and the technical challenges of MRIgRT were reviewed in this article.
作者 毛玲丽 刘红冬 阳露 裴曦 徐榭 MAO Lingli;LIU Hongdong;YANG Lu;PEI Xi;Xie George XU(School of Physical Science,University of Science and Technology of China,Hefei 230025,China;Center of Radiotherapy,Guangzhou MunicipalTumor Hospital,Guangzhou 510095,China)
出处 《中国医学影像技术》 CSCD 北大核心 2019年第4期605-609,共5页 Chinese Journal of Medical Imaging Technology
基金 国家自然科学基金面上项目(11575180) 国家重点研发计划(2017YFC0107500) 安徽省重点研究与开发计划(1804a09020039)
关键词 磁共振成像 放射疗法 设备设计 magnetic resonance imaging radiotherapy equipment design
  • 相关文献

参考文献3

二级参考文献36

  • 1BOSTICK W H. Possible techniques in direct-electron beam tumour therapy[J]. Phys Rev. 1950. 77(4): 564-565. 被引量:1
  • 2WEINHOUS M S. NATH R. SCHULZ RJ. Enhancement of electron beam dose distributions by longitudinal magnetic fields: Monte Carlo simulations and magnet system optimization[J]. Med Phys. 1985. 12(5): 598-603. 被引量:1
  • 3BIELAJEW A F. The effect of strong longitudinal magnetic fields on dose deposition from electron and photon beams[J]. Med Phys , 1993.20(4): 1171-1179. 被引量:1
  • 4CHEN Y. BIELAJEW A F. LITZENBERG D W. et al. Magnetic confinement of electron and photon radiotherapy dose: a Monte Carlo simulation with a nonuniform longitudinal magnetic field[J]. Med Phys. 2005. 32( 12): 3810-3818. 被引量:1
  • 5SHIH C c. High energy electron radiotherapy in a magnetic field[J]. Med Phys. 1975. 2(l): 9-13. 被引量:1
  • 6NARDI E. BARNEA G. Electron beam therapy with transverse magnetic fields[J]. Med Phys. 1999.26(6): 967-973. 被引量:1
  • 7LEE M C. MA C M. Monte Carlo characterization of clinical electron beams in transverse magnetic fields[J]. Phys Med Bioi. 2000. 45(l0): 2947-2967. 被引量:1
  • 8WHITMIRE D P. BERNARD D L, PETERSON M D. et al. Magnetic enhancement of electron dose distribution in a phantom[J]. Med Phys , 1977. 4(2): 127-131. 被引量:1
  • 9NATH R. SCHULZ RJ. Modification of electron-beam dose distributions by transverse magnetic fields[J]. Med Phys , 1978.5(3): 226-2;,0. 被引量:1
  • 10PALIWAL B R. WILEY A L.JR. WESSELS B W. et al. Magnetic field modification of electron-beam dose distributions in inhomogeneous media[J]. Med Phys. 1978. 5(5): 404-408. 被引量:1