期刊文献+

一种基于新三维随机Hough变换的航迹起始算法 被引量:2

A New Track Initiation Algorithm Based on 3D Randomized Hough Transform
下载PDF
导出
摘要 针对雷达跟踪多目标时,目标点迹受杂波、噪声等因素影响,航迹起始难度大的问题,利用三维空间直线表示方法提出了一种4参数三维Hough变换算法。该算法是对传统二维Hough变换的拓展,它结合了传统的二维随机Hough变换理论,是一种新的三维随机Hough变换算法。通过该算法对理论数据和实测数据进行验证,结果表明,对于航迹区别较大的目标,该算法的航迹起始成功概率为98.5%;对于空间航迹相近的目标,该算法可成功将目标航迹从杂波中提取出来,虽然可能会出现航迹混淆,但利用目标先验信息可解决该问题,实现航迹起始。 When radar tracks multiple targets,the tracks under dense pulse jamming and fragmentary plots of false target jamming are hard to initiate.To solve the problem,a new four parameter 3D Hough transform algorithm based on representation of straight lines in the 3D space is proposed.In combination with the traditional random Hough transform theory,a new 3D randomized Hough transform is developed,which is an extension of the traditional 2D randomized Hough transform.Simulation results of simulated data and measured data show that the proposed algorithm successfully initiates the track with a probability of 98.5% to tracks that are not close.To the tracks that are quite close,the algorithm can extract tracks from clutter or jamming points.Although target tracks may be mixed up,the initiation can be finished with a priori information.
出处 《飞行器测控学报》 CSCD 2014年第1期30-34,共5页 Journal of Spacecraft TT&C Technology
关键词 三维Hough变换 四参数Hough变换 随机HOUGH变换 速度限制 航迹起始 3D Hough transform 4-parameter Hough transform randomized Hough transform velocity limit track
  • 相关文献

参考文献9

二级参考文献20

  • 1Fenster A, Downey D B, Cardinal H N. Topical Review: Three-Dimensional Ultrasound Imaging[J]. Physics in Medicine and Biology, 2001,46(5): 67-99. 被引量:1
  • 2Janvier M A, Destrempes F, Soulez G,et al. Validation of a New 3D-US Imaging Robotic System to Detect and Quantify Lower Limb Arterial Stenoses[C]//Proc of IEEE Engineering in Medicine and Biology Society, 2007:339-342. 被引量:1
  • 3Wesarga S, Firlea E A, Schwald B. Accuracy of Needle Implantation in Brachytherapy Using a Medical AR System a Phantom Study[C]//Proc of SHE Int'l Syrup on Medical Imaging, 2004 : 1609-1620. 被引量:1
  • 4Loser M H, Navab N. A New Robotic System for Visually Controlled Percutaneous Interventions under CT Fluoroscopy [C]//Proc of the 3rd Int'l Conf on Medical Image Computing and Compute-Assisted Intervention, 2000: 887-896. 被引量:1
  • 5Di Maio S P, Kacher D F, Ellis R E, et al. Needle Artifact Localization in 3T MR Images[J].Stud Health Teehnol Inform,2006,119 : 120-125. 被引量:1
  • 6Ding M, Wei Z, Gardi L, et al. Needle and Seed Segmentation in IntraOperative 3D Ultrasound-Guided Prostate Brachytherapy[J]. Ultrasonics, 2006,44 (S1) : 331-336. 被引量:1
  • 7Ding M, Cardinal H N. Automatic Needle Segmentation in Three-Dimensional Ultrasound Images Using Two Orthogonal Two-Dimensional Image Projections[J].Medieal Physics, 2003,30(2) : 222-234. 被引量:1
  • 8Roberts K S. A New Representation for a Line[C]//Proc of Computer Society Conf Computer Vision and Pattern Recognition, 1988: 635-640. 被引量:1
  • 9Illingworth J,Kittter J. A Survey of the Hough Transform [J].Computer Vision, Graphics and Image Process, 1988, 44(1):87 -116. 被引量:1