期刊文献+

谷胱甘肽稳定的CdTe量子点荧光猝灭法测定痕量过氧化氢 被引量:3

Determination of Trace Hydrogen Peroxide by Fluorescence Quenching Method of Glutathione-capped CdTe Quantum Dots
下载PDF
导出
摘要 以谷胱甘肽稳定的CdTe量子点作为荧光探针,基于荧光猝灭法对过氧化氢进行了定量检测,考察了缓冲溶液体系、量子点浓度、反应时间等多种因素的影响。实验结果表明,在pH=7.2的Na2HPO4-NaH2PO4缓冲液中,反应时间为15min,过氧化氢浓度为1.0×10-6~3.0×10-5 mol/L范围时,其线性回归方程为△F=9.78+7.56c(10-6 mol/L),线性相关系数和检测限分别为0.9992和1.27×10-8 mol/L。谷胱甘肽稳定的CdTe量子点荧光猝灭法已用于水样的测定,回收率在96%~103%之间,相对标准偏差RSD不大于3.3%,结果令人满意。 By using glutathione-capped CdTe quantum dots (QDs) as a fluorescent (PL) probe, a new flu- orescence quenching method was developed to quantitatively determine hydrogen peroxide based on PL quenching effect of CdTe QDs. The influences of buffer solution, QDs concentration and incubation time on the fluorescence behavior of QDs were investigated. The results indicated that in a Na2 HPO4-NaH2 PO4 buffer solution at pH=7.2 and with 15 min incubation, the determined concentration of hydrogen peroxide was in the ranges of 1.0×10^6-3.0× 10^5 mol/L. The fluorescence intensity of CdTe QDs and the con- centration of hydrogen peroxide follow the linearly fitted equation as. △= 9.78+7.56c (10^6 mol/L) with the correlation coefficient of 0. 9992. The detection limit was 1.27× 10^8 mol/L. The fluorescence quenching method of glutathione-capped CdTe QDs has been applied to analyze water samples. The recov- eries were between 96%to 103% and relative standard deviation of the method was less than 3.3%, which were satisfactory.
出处 《中国无机分析化学》 CAS 2012年第2期10-13,共4页 Chinese Journal of Inorganic Analytical Chemistry
基金 安徽省优秀青年人才基金项目(2009SQRZ173ZD) 宿州学院大学生科研项目(KYLXLKYB11-15)资助
关键词 谷胱甘肽 CDTE量子点 过氧化氢 荧光猝灭 rds glutathione CdTe quantum dots hydrogen peroxide fluorescence quenching
  • 相关文献

参考文献13

二级参考文献133

共引文献97

同被引文献28

  • 1谢海燕,庞代文.Ⅱ-Ⅵ型量子点制备及其在生物检测中应用研究进展[J].分析化学,2004,32(8):1099-1103. 被引量:39
  • 2杨冬芝,徐淑坤,陈启凡.量子点的荧光特性在生物探针方面的应用[J].光谱学与光谱分析,2007,27(9):1807-1810. 被引量:22
  • 3Chandrakant K T, Sreekantha R D, Rohini A, et al. Green synthesis of silver nanoparticles and their appli- cation for the development of optical fiber based hydro- gen peroxide sensor[J]. Sensors and Actuators B: Chemical, 2013(183) :144-149. 被引量:1
  • 4Miao Y E, He X, Zhong Y,et al. A novel hydrogen per- oxide sensor based on Ag/SnO2 composite nanotubes by electrospinning[J]. J, Electrochimica Acta, 2013(99): 117-123. 被引量:1
  • 5Liu M, Liu R, Chen W. Graphene wrapped Cu20 nanocubes: Non-enzymatic electrochemical sensors for the detection of glucose and hydrogen peroxide with en- hanced stability [J]. Biosensors and Bioelectronics, 2013(45) :206-212. 被引量:1
  • 6Lu Q, Dong X, Li L, et al. Direct electrochemistry- based hydrogen peroxide biosensor formed from single- layer graphene nanoplatelet-enzyme composite film[J].Talanta, 2010(82) ; 1344-1348. 被引量:1
  • 7Par zdzioch-Czochra M, Wide' nska A. Spectrofluorimetric determination of hydrogen peroxide scavenging activity [J]. Analytica Chimica Acta, 2002(452) :177-184. 被引量:1
  • 8Hanaoka S, Lin J. M, Yamada M. Chemiluminescent flow sensor for H20z based on the decomposition of H2 02 cata- lyzed by cobalt (Ⅱ)-ethanolamine complex immobilized on resin[J]. Analytica Chimica Acta, 2001 (426) : 57-64. 被引量:1
  • 9Aslan K, Malyn S. N, Geddes C. D. Multicolor micro- wave-triggered metal-enhanced chemiluminescence[J]. J. Am. Chem. Soc, 2006(128):13372-13373. 被引量:1
  • 10Zhang S, Tang S, Lei J,et al. Functionalization of gra- phene nanoribbons with porphyrin for eleetrocatalysis and amperometric biosensing[J]. Journal of Electroana lytical Chemistry, 2011(656) :285-288. 被引量:1