期刊文献+

自动顶空-气相色谱-质谱法测定血液中乙醇含量 被引量:16

GC-MS Determination of Ethanol in Blood with Auto-headspace Sample Introduction
下载PDF
导出
摘要 提出了自动顶空-气相色谱-质谱联用检测血液中乙醇含量的方法。取一定量的血样或乙醇标准样品置于顶空瓶中(其中各加固定量的叔丁醇作为内标),在60 ℃及中速振摇的条件下平衡20 min,通过进样环定量地将一定量样品引入于气相色谱-质谱联用仪器中进行测定。乙醇和叔丁醇的保留时间分别为1.47 min和1.56 min。方法的线性范围为0.01-10.00 g·L-1,检出限(3S/N)为0.6 mg·L-1,测定下限(10S/N)为1.0 mg·L-1。乙醇的回收率在92%-105%之间,测定值的相对标准偏差(n=6)小于7%。 A method for the determination of ethanol in blood by GC-MS with auto-headspace sample introduction was proposed. The blood sample or ethanol standard (together with a definite amount of tert. -butanol as internal standard) was placed in the head-space bottle and equilibrated at 60 ℃ for 20 rain with moderate-speed- shaking. Definite amount of sample was quantitatively introduced into the GC-MS instrument through the sample introduction loop. Retention time of ethanol and tert.-butanol was found at 1.47 rain and 1.56 min, respectively. Linear relationship between values of peak area and mass concentration of ethanol was obtained in the range of 0. 01--10. 00 g . L-1 with values of detection limit (3S/N) of 0. 6 mg . L-1 and lower limit of determination (10S/N) of 1.0 mg . L-1. The values of recovery of ethanol was found in the range from 92% to 105%, with RSD (n=6) less than 7%.
出处 《理化检验(化学分册)》 CAS CSCD 北大核心 2010年第1期22-24,共3页 Physical Testing and Chemical Analysis(Part B:Chemical Analysis)
关键词 乙醇 自动顶空进样 气相色谱-质谱法 血液 Ethanol Auto-headspace injection GC-MS Blood
  • 相关文献

参考文献5

二级参考文献11

共引文献26

同被引文献216

引证文献16

二级引证文献97

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部