期刊文献+

超声造影评价兔肝炎性假瘤及VX2肝癌血流灌注的实验对照研究 被引量:3

Control study of hepatic inflammatory pseudoneoplasm and VX2 carcinoma perfusion in rabbits by contrast-enhanced ultrasonography
下载PDF
导出
摘要 目的应用实时超声造影成像技术及时间-强度曲线,观察兔肝炎性假瘤和转移性VX2肝癌的血流灌注方式。方法荷炎性假瘤和荷VX2肝癌实验兔各10只,经耳缘静脉团注法注射超声造影剂SonoVue后,应用CnTI低机械指数实时灰阶成像技术和定量时间-强度曲线(Washin-WashoutCurve)软件,观察分析各时相肿瘤结节及周围正常肝组织的动态增强过程。结果与正常肝实质相比较,炎性假瘤造影增强与肝实质同步,二者造影始增时间、峰值时间、增强时间、始消时间无显著性差别(P>0.05)。VX2肝癌强化呈典型的"快进快出"型,早期动脉相快速增强,门脉相与延迟相肿瘤结节内造影剂迅速廓清,表现为负性显影,VX2肝癌始增时间、峰值时间、增强时间、始消时间显著早于正常肝实质(P<0.05)。VX2肝癌与炎性假瘤比较,VX2肝癌造影始增时间、峰值时间、始消时间显著早于炎性假瘤(P<0.05)。结论低机械指数实时超声造影成像,可提供肝脏局灶性结节的动态血流灌注信息,结合时间-强度曲线定量分析,对肝肿瘤的诊断和鉴别诊断具有较佳的实用价值。 Objective To analysis the perfusion of hepatic inflammatory pseudoneoplasm(IPL)and VX2 carcinoma in rabbits by real-time contrast-enhanced ultrasound and time intensity curve.Methods Ten rabbits with IPL and 10 rabbits with VX2 carcinoma were studied by low mechanical index(MI)contrast-enhanced ultrasound with bolus injection of SonoVue via peripheral vein respectively.Corresponding parameters such as time to enhancement(ET),time to peak intensity(PIT),time to ascent(AT)and time to lighten(LT)were measured by CnTI(contrast tuned imaging)technique and time intensity curve.Results Real-time contrast-enhanced imaging clearly delineated the dynamic enhancement of the tumors and liver parenchyma during the whole phase.IPL showed the same enhanced features as that of liver parenchyma.There was no significant difference for ET,PIT,AT and LT between IPL and parenchyma(P〉0.05).VX2 tumors showed hyperechoic enhancement in arterial phase and hypoechoic enhancement was observed in the portal and delayed phase comparedto the hepatic parenchyma around the tumor lesions.The ET,PIT and LT were significantly earlier and the AT significantly shorter in VX2 carcinoma than those of the liver parenchyma(P〈0.05).The ET,PIT and LT of IPL were significantly later than those of VX2 tumors(P〈0.05).Conclusion Low mechanical index contrast-enhanced ultrasound provided enough information of perfusion for VX2 carcinoma and IPL.Real-time contrast-enhanced ultrasound is a useful technique in differential diagnosis of hepatic focal lesions combined with time intensity curve.
出处 《中国医学影像技术》 CSCD 北大核心 2008年第8期1153-1156,共4页 Chinese Journal of Medical Imaging Technology
基金 山西省科技厅攻关项目基金(051095-3)
关键词 超声检查 介入性 炎性假瘤 VX2肿瘤 时间-强度曲线 Ultrasonography,interventional Inflammatory pseudoneoplasm VX2 carcinoma Time intensity curve
  • 相关文献

参考文献7

二级参考文献15

  • 1Barinaga M. Designing therapies that target tumor blood vessels. Seienee, 1997,275 : 482-484. 被引量:1
  • 2Yicheng NI,Guy M,Johan M,et al. Magnetic resonance imaging, mieroangiography,and histology in a rat model of primary liver cancer. Invest Radiol, 1992,27:689-697. 被引量:1
  • 3Klein D,Jenett M,Gassel HJ, et al. Quantitative dynamic contrastenhanced sonography of hepatic tumors. Eur Radiol, 2004, 14: 1082-1091. 被引量:1
  • 4Byun JH, Yang DH, Yoon SE, et al. Contrast-enhancing hepatic eosinophilic abscess during the hepatic arterial phase: a mimic of hepatocellular carcinoma. Am J Roentgenol, 2006,186 : 168-173. 被引量:1
  • 5Garcia-Eulate R, Hussain N, Heller T, et al. CT and MRI of hepatic abscess in patients with chronic granulomatous disease. Am J Roentgenol, 2006,187: 482-490. 被引量:1
  • 6Catalano D,Sandomenieo F,Raso MM,et al. Low mechanical index contrast enhanced sonographic findings of pyogenic hepatic abscess. Am J Roentgenol, 2004,182: 447-450. 被引量:1
  • 7Lim JH, Lee WJ, Lee DH, et al. Hyperosinophilie syndrome: CT findings in patients with hepatic lobar or segmental involvement. Kerean J Radiol, 2000,1 : 98-103. 被引量:1
  • 8Quaia E, Calliada F, Bertolotto M, et al. Characterization of local liver lesions with contrast specific US modes and a sulfur hexafluoride-filled microbubble contrast agent : diagnostic performance and confidence. Radiology, 2004,232 : 420-430. 被引量:1
  • 9Quaia E, Degobbis F, Tona G, et al. Differential patterns of contrast enhancement in different focal liver lesions after injection of the microbubble US contrast agent SonoVue. Radiol Med, 2004, 107 : 155-165. 被引量:1
  • 10Hohmann J, Skrok J, Puls R, et al. Characterization of focal liver lesions with contrast-enhanced low MI real time ultrasound and SonoVue. Rofo,2003,175 : 835-843. 被引量:1

共引文献7

同被引文献32

引证文献3

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部