摘要 炼钢用中频电炉不仅产生大量的谐波,污染电网,影响电能质量,增加设备损耗,而且用户本身的无功补偿电容器也无法正常使用,致使功率因数低下。本文通过对一中频电炉用户进行谐波测量和分析,实施综合治理方案,提出了同类问题的解决方案。 Because intermediate frequency induction electric furnace used for steel-making will produce a lot of harmonic, it will make the power net polluted, affect the electric power quality, and increase the equipments'spoilage. In the mean time, consumers'capacitors can't be in good working condition, and the power factor is reduced. In this paper, by measuring and analyzing the harmonic of clients'intermediate frequency induction electric furnace and implementing the comprehensive management schemes, it can provide the solution to similar problems.
作者 杨波 咸日常
机构地区 淄博供电公司
出处 《电力电容器》 2006年第5期17-20,共4页 Power Capacitors
关键词 中频电炉 谐波治理 无功补偿 应用 Intermediate frequency induction electric furnace Harmonic prevention Reactive power compensation Implementation
  • 相关文献

参考文献2

  • 1GB/T14549—1993,电能质量公用电网谐波[S]. 被引量:4
  • 2周勇,罗玉.电容器谐波放大问题分析[A].第二届电能质量国际研讨会论文集[C]. 被引量:1