考虑次要失步机群的大区电网失步解列配置 被引量:3

Configuration of Large-scale Power System Out-of-step Separation Considering Minor Out-of-step Generations
下载PDF
导出
摘要 通过对大规模电网的失步仿真研究发现,当系统失步时失步机群可能会呈现为主要失步机群和次要失步机群2种失步模式。主要失步机群决定着整个大区电网的失步中心断面联络线,而次要失步机群不能决定整个大区电网的失步中心断面联络线。该现象将导致通过捕捉失步断面电压最低点(失步中心)寻找失步断面联络线的方法一般只能将主要失步机群分开,却未必能够将次要失步机群也合理分布到与之同调的机群之中。因此,工程中应结合系统离线仿真分析,尽可能对有可能成为次要失步模式的机组安装失步解列装置,以作为一种后备,防止次要失步模式机组扰动系统,造成事故扩大。 Through the simulation analysis of large-scale power system, it is found that the out-of-step generators may behave in two groups, the main out-of-step generator groups and the minor out-of-step generator groups. The main out-of-step generator groups can determine the out-of-step center interface tie-lines of large-scale power system, but the minor out-of-step generator groups cannot. This phenomenon facilitates a method of capturing the out-of-step center interface tie-lines, based on searching the lowest voltage points (center of out-of-step) during the system out-of-step state. By doing so, the main out-of-step generator groups can be identified. But the method maybe fails to split the minor out-of-step generators into the correct coherent out-of-step generator groups. Hence, in engineering practice, the generators which are likely to be in the minor ou-of- step groups should be equipped with the out-of-step separation equipment based on the off-line system analysis. Thus with the backup of the separation devices, further accident will be avoided.
出处 《电力系统自动化》 EI CSCD 北大核心 2006年第17期50-53,107,共5页 Automation of Electric Power Systems
关键词 失步解列 失步中心 失步断面 主要失步机群 次要失步机群 system separation center of out-of-step out-of-step interface main out-of-step generations minor out-of-step generations
  • 相关文献

参考文献14

二级参考文献116

共引文献928

同被引文献46

引证文献3

二级引证文献41

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部