期刊文献+

凝汽器真空度降低原因分析及诊断方法 被引量:3

Analysis on reasons of lowering of condenser vacuum degree and diagnosis method
下载PDF
导出
摘要 介绍了反映凝汽器运行状况的参数,分析了凝汽器真空度偏低的影响因素及诊断依据,通过实例阐述了机组正常运行期间真空度降低的诊断方法。提出了极限真空度和最佳真空度的概念,可为指导汽轮机组经济运行提供参考。 The parameters reflecting the condenser operation conditions were introduced. The influencing factors,which cause the condenser vacuum degree to lower,were analyzed,and the diagnosis basis of the factors was explained. The diagnosis method of vacuum degree lowering in normal unit operation was illustrated by practical example,and the concepts of extreme vacuum degree and optimal vacuum degree were put forward. The results in this paper can be used as reference for economical operation of steam turbine unit.
作者 王刚
出处 《华电技术》 CAS 2015年第3期34-37,77,共4页 HUADIAN TECHNOLOGY
关键词 凝汽器 真空度 排汽温度 循环水温升 端差 最佳真空度 极限真空度 condenser vacuum degree exhaust temperature temperature rising of circulating water terminal difference optimal vacuum degree extreme vacuum degree
  • 相关文献

参考文献3

  • 1纪昌宏.汽轮机运行及事故处理[M].北京:化学工业出版社,2011. 被引量:1
  • 2蒋明昌编著..火电厂能耗指标分析手册[M].北京:中国电力出版社,2011:629.
  • 3陈义森.汽轮机冷端系统运行分析[R].济南:山东电力研究院,2011. 被引量:1