期刊文献+

非接触式角膜内皮镜SP-3000P测量中央和周边角膜厚度的重复性研究 被引量:2

下载PDF
导出
摘要 中央角膜厚度(central corneal thickness,CCT)可以显示角膜内皮泵的功能,反映包括角膜内皮失代偿、角膜扩张、角膜水肿、青光眼、球形角膜和干眼等一些眼前节疾病。然而,周边角膜厚度的报道较少,主要原因是周边角膜厚度测量时难以准确定位。非接触式角膜内皮镜已成为测量角膜厚度的一种常用方法,其检查具有非侵入性,可以在角膜中央和周边聚焦测量相应部位的厚度,同时可以测量角膜内皮细胞的密度和形态。
出处 《中华实验眼科杂志》 CAS CSCD 北大核心 2012年第3期287-288,共2页 Chinese Journal Of Experimental Ophthalmology
  • 相关文献

参考文献4

  • 1Waring GO, Bourne WM, Edelhauser HF. The corneal endothelium. Normal and pathologic structure and function[ J]. Ophthalmology, 1982, 89:531-590. 被引量:1
  • 2Cho P, Cheung SW. Central and peripheral corneal thickness measured with the TOPCON specular microscope SP-2000P [ J]. Curr Eye Res, 2000, 21:799-807. 被引量:1
  • 3Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement [ J ]. Int J Nurs Stud, 2010, 47:931-936. 被引量:1
  • 4Ogbuehi KC, Almubrad TM. Repeatability of central corneal thickness measurements measured with the Topcon SP2000P specular microscope [ J ]. Graefe' s Arch Clin Exp Ophthalmol, 2005, 243:798-802. 被引量:1

同被引文献16

  • 1刘瑄,朱萍.应用简化细胞分析软件进行角膜内皮细胞图像定量分析的可靠性研究[J].眼科,2007,16(6):421-424. 被引量:1
  • 2Goldich Y, Marcovich AL, Barkana Y, et al. Comparison ofcomeal endothelial cell density estimated with 2 noncontact specularmicroscopes. European Journal of Ophthalmology, 2010, 20:825-830. 被引量:1
  • 3Almubrad TM. Comparison of the precision of the Topcon SP-3000Pspecular microscope and an ultrasound pachymeter. ClinicalOphthalmology, 2011,5: 871-876. 被引量:1
  • 4Dou^ityMJ,Muller A, ZamanML Assessment of the reliability ofhuman comeal endothelial cell-density estimates using a noncontactspecular microscope. Cornea,2000,19 : 148-158. 被引量:1
  • 5Binder PS, Akers P, Zavala EY. Endothelial cell densitydetermined by specular microscopy and scanning electronmicroscopy. Ojithalmolty, 1979 , 86: 1831-1847. 被引量:1
  • 6Doughty MJ,Fonn D, Nguyen KT. Assessment of the reliability ofcalculations of the coefficient of variation for normal andpolymegethous human comeal endothelium. Optometry & VisionScience, 1993,70: 759-770. 被引量:1
  • 7McCareyBE, Edelhauser HF, Lynn MJ. Review of comealendothelial specular microscopy for FDA clinical trials of refractiveprocedures, surgical devices, and new intraocular drugs andsolutions.Cornea, 2008, 27: 1-16. 被引量:1
  • 8Hirst LW, Yamauchi K, Enger C, etal. Quantitative analysis ofwide-field specular nucroscopy. II. Precision of sampling from thecentral comeal endothelium. Invest Ophthalmol Vis Sci, 1989,30: 1972-1979. 被引量:1
  • 9Lass JH, Gal RL, Ruedy KJ, et al. An evaluation of imagequality and accuracy of eye bank measurement of donor corneaendothelial cell density in the Specular Microscopy Anciliaiy Study.Ophthalmology, 2005, 112: 431-440. 被引量:1
  • 10潘晓平,倪宗瓒.组内相关系数在信度评价中的应用[J].华西医科大学学报,1999,30(1):62-63. 被引量:106

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部