牙种植体挤压植入后早期界面骨骨密度的X线影像分析 被引量:5

Analysis of early changes in bone density around the dental implants compressed into mandible of small pigs by digital radiography
下载PDF
导出
摘要 目的观察牙种植体挤压植入后界面骨的骨密度变化。方法在小型猪双侧前磨牙区挤压植入CompressR种植体(IGZ)。拍摄种植体/骨的数码X线根尖片影像。垂直于种植体长轴提取分析平面,统计分析基础骨密度分别与挤压后的骨密度和骨密度变化区域的相关性。结果挤压后的骨密度增加,基础骨密度与挤压后骨密度的相关系数r=0.8,P=0.00,与骨密度变化区域的相关系数r=-0.49,P=0.00;在同一分析平面种植体两侧的骨组织配对,基础骨密度与骨密度变化区域负相关占79.2%。结论骨挤压增加种植体界面骨的密度,提高初期稳定性。手术前的骨密度分析有助于种植方案的制定,植入前的基础骨密度影响种植体的稳定性;相同挤压距离下基础骨密度越大初期稳定性越好,但疏松骨质较密质骨能耐受更大的挤压距离。 Objective To observe the early changes in bone density around implants compressed into mandibles of small pigs by digital radiography. Methods Dental implants were compressed into premolar areas of both sider of mandibles of three small pigs. Digital radiograms were taken within 7 days. The densities of interracial bones were analyzed. The basal gray values (optical densities), the changed gray values, and the widths of changed densities were measured. The correlations between the basal gray values and increased gray values and the width of changed densities were examined. Results There were a positive correlation ( r = 0.8, P = 0.00) between basal gray values and increased gray values, and a negative correlation ( r = -0.49, P = 0.00) between basal gray values and the widths of changed densities; if the data were paired for both sides of mandibles at the same level, the negative correlation coefficient for the basal gray values and cvidths of changed densities was - 0.79. Conclusion The insertion of implants into the compressed bone increases the interracial bone density. The basal bone density affects the stability of implants. At the same compressed distance, the stability of implants in the bone with higher density is higher than that in the bone with lower density. Cancellous bone can endure more compressed distance than compact bone.
出处 《武警医学》 CAS 2005年第11期829-832,共4页 Medical Journal of the Chinese People's Armed Police Force
关键词 牙种植 骨挤压 数码X影像 Dental implants Bone compression Digital radiography
  • 相关文献

参考文献10

  • 1Adell R, Lekholm U, Rockler B et al .A 15 - year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surgery, 1981,10:387 - 416 被引量:1
  • 2李晓宁,樊瑜波,雷文涛,蒋文涛,蒲放,陈君楷.指定位移时牙种植体周围颌骨组织应力的三维有限元分析[J].航天医学与医学工程,2002,15(3):195-198. 被引量:1
  • 3Weinan H, Huiskes R, Grootenboer H-J. Effects of material properties of femoral hip components on bone remodeling. J Orthprdic Reserch, 1992,10:845- 853 被引量:1
  • 4Huiskes R, Ruimerman R, van Lenthe G- H et al . Effects of mechanical forces on maintenance and adaptation of form in trabecular bone. Nature, 2000,405:704- 706 被引量:1
  • 5Maki K, Okano T, Morohashi T et al. The application of three- dimensional quantitative computed tomography to the maxillofacial skeleton. Dentomaxillofacial Radiology, 1997,26:39 - 44 被引量:1
  • 6Appleton RS, Nummikoski PV, Pigno MA et al .A radiographic assessment of progressive loading on bone around single osseointegrated implants in the posterior maxilla. Clin Oral Implant Res, 2005,16:161 - 172 被引量:1
  • 7Bottcher J, Pfeil A, Rosholm A et al . Influence of imagecapturing parameters on digital x- ray radiogrammetry. J Gin Densitom, 2005, 8: 87 - 94 被引量:1
  • 8杨德圣,刘洪臣,董军,刘海亮.骨质量和种植体螺纹对种植稳定性影响的三维有限元分析[J].口腔颌面修复学杂志,2005,6(2):118-120. 被引量:15
  • 9Strietzel F- P, Nowak M, Kǔchler I et al . Peri- implant alveolar bone loss with respect to bone quality after use of the osteotome technique. Clin Oral Impl Res, 2002, 13:508-513 被引量:1
  • 10Nikellis I, Levi A, Nicolopoulos C et al . Immediate loading of 190 endosseous dental implants: A prospective observational study of 40 patient treatments with up to 2- year data. Int J Oral Maxillofac Implants, 2003,14:180- 187 被引量:1

二级参考文献13

  • 1Brunski JB. Avoid pitfalls of overloading and micromotion of intraosseous implants[J]. Dent Implant Update, 1993,4 (1):77~ 81 被引量:1
  • 2Chun H-J, CheongS-Y, HanS-J, etal. Evaluation of design parameters of osseointegrated dental implants using finite element analysis[J]. J Oral Rehabitation 2002,29: 565 ~ 574 被引量:1
  • 3Rieger MR, Fareed K, Adams WK, et al. Bone stress distribu tion for three endosseous implants. J Prosthet Dent 1989,61(2): 223 ~ 228 被引量:1
  • 4Rieger MR, Mayberry M, Brose MO. Finite element analysis of six endosseous implants[J]. J Prosthet Dent. 1990, 63 (6):671 ~ 676 被引量:1
  • 5Huang H-M, Lee S-Y, The C-Y,et al. Resonance frequency assessment o f dentlimplant stability with variousbonequalities:anumerical approach[J]. Clin Oral Impl Res, 2002, 13:65~74 被引量:1
  • 6Tada S, Stegaroiu R, Kitamura E, et al. Influence of implant design and bone quality on stress/strain distribution in bone around implants: A 3-dimensional finite element analysis Int [J]. J Maxillofac Implants, 2003,18 (3):357~368 被引量:1
  • 7Hedia H-S. Stress and strain distribution behavior in the bone due to the effect of cancellous bone, dental implant mate rial and the bone height[J]. Biomedical Material Eng, 2002,12 (2):111~ 119 被引量:1
  • 8Akca K, Cehreli MC, Iplikcioglu H A comparison of threedimensional finite element stress analysis with in vitro strain gauge measurements on dental implants[J]. Int J Prosthodont,2002 , 15 (2): 115~ 121 被引量:1
  • 9Pierrisnard L, Hure G, Barquins M, et al. Two dental implants designed for immediate loading:A finite element analysis[J]. Int J Maxillofac Implants, 2002, 17 (3) : 353 ~ 362 被引量:1
  • 10da Cunha H-A, Fduardo C-E, Filho H-N, et al.A compa rison between cutting torque and resonance frequency in the assessment of primary stability and final torque capacity of standard and TiUnite single tooth implants under immediate loading[J]. Int J Oral Maxillofac Implants 2004,19: 578~ 585 被引量:1

共引文献14

同被引文献79

引证文献5

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部